Effluent disposal
News •
Desalination produces fresh water but also a significant volume of waste effluent, called brine. Since the primary pollutant in the brine is salt, disposal in the ocean is generally not a problem for facilities located near a coastline. At inland desalination facilities, care must be taken to prevent pollution of groundwater or surface waters. Methods of brine disposal include dilution, evaporation, injection into a saline aquifer, and pipeline transport to a suitable disposal point.
Water distribution
A water distribution system is a network of pumps, pipelines, storage tanks, and other appurtenances. It must deliver adequate quantities of water at pressures sufficient for operating plumbing fixtures and firefighting equipment, yet it must not deliver water at pressures high enough to increase the occurrence of leaks and pipeline breaks. Pressure-regulating valves may be installed to reduce pressure levels in low-lying service areas. More than half the cost of a municipal water supply system is for the distribution network.
Pipelines
The pipeline system of a municipal water distribution network consists of arterial water mains or primary feeders, which convey water from the treatment plant to areas of major water use in the community, and smaller-diameter pipelines called secondary feeders, which tie in to the mains. Usually not less than 150 mm (6 inches) in diameter, these pipelines are placed within the public right-of-way so that service connections can be made for all potential water users. The pipelines are usually arranged in a gridiron pattern that allows water to circulate in interconnected loops; this permits any broken sections of pipe to be isolated for repair without disrupting service to large areas of the community. “Dead-end” patterns may also be used, but they do not permit circulation, and the water they provide is more susceptible to taste and odour problems because of stagnation.
A water distribution pipeline must be able to resist internal and external forces, as well as corrosion. Pipes are placed under stress by internal water pressure, by the weight of the overlying soil, and by vehicles passing above. They may have to withstand water-hammer forces; these occur when valves are closed too rapidly, causing pressure waves to surge through the system. In addition, metal pipes may rust internally if the water supply is corrosive or externally because of corrosive soil conditions.
Materials
Distribution pipes are made of asbestos cement, cast iron, ductile iron, plastic, reinforced concrete, or steel. Although not as strong as iron, asbestos cement, because of its corrosion resistance and ease of installation, is a desirable material for secondary feeders up to 41 cm (16 inches) in diameter. Pipe sections are easily joined with a coupling sleeve and rubber-ring gasket. Cast iron has an excellent record of service, with many installations still functioning after 100 years. Ductile iron, a stronger and more elastic type of cast iron, is used in newer installations. Iron pipes are provided in diameters up to 122 cm (48 inches) and are usually coated to prevent corrosion. Underground sections are connected with bell-and-spigot joints, the spigot end of one pipe section being pushed into the bell end of an adjacent section. A rubber-ring gasket in the bell end is compressed when the two sections are joined, creating a watertight, flexible connection. Flanged and bolted joints are used for aboveground installations.
Plastic pipes are available in diameters up to 61 cm (24 inches). They are lightweight, easily installed, and corrosion-resistant, and their smoothness provides good hydraulic characteristics. Plastic pipes are connected either by a bell-and-spigot compression-type joint or by threaded screw couplings.
Precast reinforced concrete pipe sections up to 366 cm (12 feet) in diameter are used for arterial mains. Reinforced concrete pipes are strong and durable. They are joined using a bell-and-spigot-type connection that is sealed with cement mortar. Steel pipe is sometimes used for arterial mains in aboveground installations. It is very strong and lighter than concrete pipe, but it must be protected against corrosion with lining of the interior and with painting and wrapping of the exterior. Sections of steel pipe are joined by welding or with mechanical coupling devices.
Fittings
In order to function properly, a water distribution system requires several types of fittings, including hydrants, shutoff valves, and other appurtenances. The main purpose of hydrants is to provide water for firefighting. They also are used for flushing water mains, pressure testing, water sampling, and washing debris off public streets.
Many types of valves are used to control the quantity and direction of water flow. Gate valves are usually installed throughout the pipe network. They allow sections to be shut off and isolated during the repair of broken mains, pumps, or hydrants. A type of valve commonly used for throttling and controlling the rate of flow is the butterfly valve. Other valves used in water distribution systems include pressure-reducing valves, check valves, and air-release valves.
Installation
Water mains must be placed roughly 1 to 2 metres (3 to 6 feet) below the ground surface in order to protect against traffic loads and to prevent freezing. Since the water in a distribution system is under pressure, pipelines can follow the shape of the land, uphill as well as downhill. They must be installed with proper bedding and backfill. Compaction of soil layers under the pipe (bedding) as well as above the pipe (backfill) is necessary to provide proper support. A water main should never be installed in the same trench with a sewer line. Where the two must cross, the water main should be placed above the sewer line.