audiometry
Learn about this topic in these articles:
hearing measurement
- In human ear: Tuning-fork tests
In the Schwabach test the presence of a sensorineural impairment is indicated when the individual being tested cannot hear the bone-conducted sound as long as the examiner with normal hearing can. The individual with a conductive hearing loss, however, can hear the fork for a longer period…